Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.946
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Med Eng Phys ; 127: 104166, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38692765

RESUMO

A profound investigation of the interaction mechanics between blood vessels and guidewires is necessary to achieve safe intervention. An interactive force model between guidewires and blood vessels is established based on cardiovascular fluid dynamics theory and contact mechanics, considering two intervention phases (straight intervention and contact intervention at a corner named "J-vessel"). The contributing factors of the force model, including intervention conditions, guidewire characteristics, and intravascular environment, are analyzed. A series of experiments were performed to validate the availability of the interactive force model and explore the effects of influential factors on intervention force. The intervention force data were collected using a 2-DOF mechanical testing system instrumented with a force sensor. The guidewire diameter and material were found to significantly impact the intervention force. Additionally, the intervention force was influenced by factors such as blood viscosity, blood vessel wall thickness, blood flow velocity, as well as the interventional velocity and interventional mode. The experiment of the intervention in a coronary artery physical vascular model confirms the practicality validation of the predicted force model and can provide an optimized interventional strategy for vascular interventional surgery. The enhanced intervention strategy has resulted in a considerable reduction of approximately 21.97 % in the force exerted on blood vessels, effectively minimizing the potential for complications associated with the interventional surgery.


Assuntos
Fenômenos Mecânicos , Vasos Sanguíneos/fisiologia , Modelos Cardiovasculares , Hidrodinâmica , Humanos , Fenômenos Biomecânicos , Modelos Biológicos , Vasos Coronários/fisiologia
2.
Arterioscler Thromb Vasc Biol ; 44(5): 1065-1085, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38572650

RESUMO

Blood vessels are subjected to complex biomechanical loads, primarily from pressure-driven blood flow. Abnormal loading associated with vascular grafts, arising from altered hemodynamics or wall mechanics, can cause acute and progressive vascular failure and end-organ dysfunction. Perturbations to mechanobiological stimuli experienced by vascular cells contribute to remodeling of the vascular wall via activation of mechanosensitive signaling pathways and subsequent changes in gene expression and associated turnover of cells and extracellular matrix. In this review, we outline experimental and computational tools used to quantify metrics of biomechanical loading in vascular grafts and highlight those that show potential in predicting graft failure for diverse disease contexts. We include metrics derived from both fluid and solid mechanics that drive feedback loops between mechanobiological processes and changes in the biomechanical state that govern the natural history of vascular grafts. As illustrative examples, we consider application-specific coronary artery bypass grafts, peripheral vascular grafts, and tissue-engineered vascular grafts for congenital heart surgery as each of these involves unique circulatory environments, loading magnitudes, and graft materials.


Assuntos
Prótese Vascular , Hemodinâmica , Humanos , Animais , Modelos Cardiovasculares , Falha de Prótese , Estresse Mecânico , Fenômenos Biomecânicos , Mecanotransdução Celular , Implante de Prótese Vascular/efeitos adversos , Desenho de Prótese , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/etiologia , Remodelação Vascular
3.
Cardiovasc Intervent Radiol ; 47(5): 533-542, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38565717

RESUMO

PURPOSE: In arterial disease, the presence of two or more serial stenotic lesions is common. For mild lesions, it is difficult to predict whether their combined effect is hemodynamically significant. This study assessed the hemodynamic significance of idealized serial stenotic lesions by simulating their hemodynamic interaction in a computational flow model. MATERIALS AND METHODS: Flow was simulated with SimVascular software in 34 serial lesions, using moderate (15 mL/s) and high (30 mL/s) flow rates. Combinations of one concentric and two eccentric lesions, all 50% area reduction, were designed with variations in interstenotic distance and in relative direction of eccentricity. Fluid and fluid-structure simulations were performed to quantify the combined pressure gradient. RESULTS: At a moderate flow rate, the combined pressure gradient of two lesions ranged from 3.8 to 7.7 mmHg, which increased to a range of 12.5-24.3 mmHg for a high flow rate. Eccentricity caused an up to two-fold increase in pressure gradient relative to concentric lesions. At a high flow rate, the combined pressure gradient for serial eccentric lesions often exceeded the sum of the individual lesions. The relative direction of eccentricity altered the pressure gradient by 15-25%. The impact of flow pulsatility and wall deformability was minor. CONCLUSION: This flow simulation study revealed that lesion eccentricity is an adverse factor in the hemodynamic significance of isolated stenotic lesions and in serial stenotic lesions. Two 50% lesions that are individually non-significant can combine more often than thought to hemodynamic significance in hyperemic conditions.


Assuntos
Simulação por Computador , Hemodinâmica , Humanos , Hemodinâmica/fisiologia , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem
4.
Biomed Phys Eng Express ; 10(3)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38447220

RESUMO

Carotid endarterectomy is the main way to combat atherosclerosis of the carotid arteries, which disrupts cerebral circulation. The generally accepted marker of atherogenesis risk are hemodynamic indices associated with near-wall shear stress. The purpose of the work is to conduct a comparative analysis of hemodynamic indices in various carotid bifurcation models. The influence of a virtual change in the geometric shape of the model in order to optimize hemodynamic indices is also being studied. On the basis of computed angiography data, carotid bifurcation models are constructed, in which critical zones of hemodynamic indices are built using computational fluid dynamics. A comparative analysis of the critical zones for different classes of models is carried out. Comparison of averaged indices for critical zones between 'normal' and post-operative groups gave more than 5-x worse results for the latter. The same results for the near-bifurcation parts of the zones give a 25% better result for postoperative models. Virtual 'removal' of insignificant plaques leads to a deterioration of the indices of up to 40% in the places of the plaque's former location. The described method makes it possible to build the indices critical zones and compare them for various types of models. A technique for virtual changing the shape of a vessel (virtual surgery) is proposed. The novelty of the approach lies in the use for comparative analysis both real vessel models and hypothetical 'improved' virtual ones, as well in the proposed division of post-operative model's critical zones into subzones of different genesis.


Assuntos
Endarterectomia das Carótidas , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/métodos , Modelos Cardiovasculares , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/cirurgia , Hemodinâmica
5.
Int J Artif Organs ; 47(4): 269-279, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38506302

RESUMO

Centrifugal blood pumps can be used for treating heart failure patients. However, pump thrombosis has remained one of the complications that trouble clinical treatment. This study analyzed the effect of impeller shroud on the thrombosis risk of the blood pump, and predicted areas prone to thrombosis. Multi-constituent transport equations were presented, considering mechanical activation and biochemical activation. It was found that activated platelets concentration can increase with shear stress and adenosine diphosphate(ADP) concentration increasing, and the highest risk of thrombosis inside the blood pump was under extracorporeal membrane oxygenation (ECMO) mode. Under the same condition, ADP concentration and thrombosis index of semi-shroud impeller can increase by 7.3% and 7.2% compared to the closed-shroud impeller. The main reason for the increase in thrombosis risk was owing to elevated scalar shear stress and more coagulation promoting factor-ADP released. The regions with higher thrombosis potential were in the center hole, top and bottom clearance. As a novelty, the findings revealed that impeller shroud can influence mechanical and biochemical activation factors. It is useful for identifying potential risk regions of thrombus formation based on relative comparisons.


Assuntos
Coração Auxiliar , Estresse Mecânico , Trombose , Trombose/etiologia , Trombose/fisiopatologia , Trombose/sangue , Humanos , Coração Auxiliar/efeitos adversos , Ativação Plaquetária , Modelos Cardiovasculares , Difosfato de Adenosina/metabolismo , Desenho de Prótese , Oxigenação por Membrana Extracorpórea/efeitos adversos , Fatores de Risco , Plaquetas/metabolismo
6.
Cardiovasc Pathol ; 70: 107626, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38458505

RESUMO

Iatrogenic damage to the cardiac conduction system (CCS) remains a significant risk during congenital heart surgery. Current surgical best practice involves using superficial anatomical landmarks to locate and avoid damaging the CCS. Prior work indicates inherent variability in the anatomy of the CCS and supporting tissues. This study introduces high-resolution, 3D models of the CCS in normal pediatric human hearts to evaluate variability in the nodes and surrounding structures. Human pediatric hearts were obtained with an average donor age of 2.7 days. A pipeline was developed to excise, section, stain, and image atrioventricular (AVN) and sinus nodal (SN) tissue regions. A convolutional neural network was trained to enable precise multi-class segmentation of whole-slide images, which were subsequently used to generate high- resolution 3D tissue models. Nodal tissue region models were created. All models (10 AVN, 8 SN) contain tissue composition of neural tissue, vasculature, and nodal tissues at micrometer resolution. We describe novel nodal anatomical variations. We found that the depth of the His bundle in females was on average 304 µm shallower than those of male patients. These models provide surgeons with insight into the heterogeneity of the nodal regions and the intricate relationships between the CCS and surrounding structures.


Assuntos
Nó Atrioventricular , Imageamento Tridimensional , Humanos , Feminino , Masculino , Recém-Nascido , Nó Atrioventricular/anatomia & histologia , Modelos Cardiovasculares , Nó Sinoatrial/anatomia & histologia , Fascículo Atrioventricular/fisiopatologia , Redes Neurais de Computação , Fatores Sexuais , Fatores Etários , Sistema de Condução Cardíaco/fisiopatologia
7.
Zhonghua Wai Ke Za Zhi ; 62(5): 467-472, 2024 May 01.
Artigo em Chinês | MEDLINE | ID: mdl-38548618

RESUMO

Computational fluid dynamics (CFD) is an emerging technology applied in the field of cardiovascular medicine, which can obtain hemodynamic data by simulating the blood flow in the patient's heart for cardiac function assessment and disease diagnosis. Left ventricular function plays a key role in the occurrence and development of cardiomyopathies and coronary disease. CFD can reconstruct the left ventricular anatomic structures of patients to clarify pathophysiologic mechanisms and analyze hemodynamic parameters to evaluate left ventricular function, verify surgical efficacy, and guide surgical strategy, which has a positive effect on achieving early diagnosis and reducing mortality from cardiomyopathies and coronary disease. At present, there are still technical limitations in the large-scale clinical application of CFD, and various solutions are being developed and tested, and further improvement and refinement are needed.


Assuntos
Cardiomiopatias , Hidrodinâmica , Função Ventricular Esquerda , Humanos , Cardiomiopatias/fisiopatologia , Função Ventricular Esquerda/fisiologia , Doença das Coronárias/fisiopatologia , Simulação por Computador , Hemodinâmica , Modelos Cardiovasculares
8.
Int J Comput Assist Radiol Surg ; 19(4): 687-697, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38206468

RESUMO

PURPOSE: Hemodynamics play an important role in the assessment of intracranial aneurysm (IA) development and rupture risk. The purpose of this study was to examine the impact of complex vasculatures onto the intra-vessel and intra-aneurysmal blood flow. METHODS: Complex segmentation of a subject-specific, 60-outlet and 3-inlet circle of Willis model captured with 7T magnetic resonance imaging was performed. This model was trimmed to a 10-outlet model version. Two patient-specific IAs were added onto both models yielding two pathological versions, and image-based blood flow simulations of the four resulting cases were carried out. To capture the differences between complex and trimmed model, time-averaged and centerline velocities were compared. The assessment of intra-saccular blood flow within the IAs involved the evaluation of wall shear stresses (WSS) at the IA wall and neck inflow rates (NIR). RESULTS: Lower flow values are observed in the majority of the complex model. However, at specific locations (left middle cerebral artery 0.5 m/s, left posterior cerebral artery 0.25 m/s), higher flow rates were visible when compared to the trimmed counterpart. Furthermore, at the centerlines the total velocity values reveal differences up to 0.15 m/s. In the IAs, the reduction in the neck inflow rate and WSS in the complex model was observed for the first IA (IA-A δNIRmean = - 0.07ml/s, PCA.l δWSSmean = - 0.05 Pa). The second IA featured an increase in the neck inflow rate and WSS (IA-B δNIRmean = 0.04 ml/s, PCA.l δWSSmean = 0.07 Pa). CONCLUSION: Both the magnitude and shape of the flow distribution vary depending on the model's complexity. The magnitude is primarily influenced by the global vessel model, while the shape is determined by the local structure. Furthermore, intra-aneurysmal flow strongly depends on the location in the vessel tree, emphasizing the need for complex model geometries for realistic hemodynamic assessment and rupture risk analysis.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Hemodinâmica , Imageamento por Ressonância Magnética , Circulação Cerebrovascular , Estresse Mecânico , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo
9.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38180888

RESUMO

OBJECTIVES: The 2 opposing inflows and 2 outflows in a total cavopulmonary connection make mechanical circulatory support (MCS) extremely challenging. We have previously reported a novel convergent cavopulmonary connection (CCPC) Fontan design that improves baseline characteristics and provides a single inflow and outflow, thus simplifying MCS. This study aims to assess the feasibility of MCS of this novel configuration using axial flow pumps in an in vitro benchtop model. METHODS: Three-dimensional segmentations of 12 single-ventricle patients (body surface area 0.5-1.75 m2) were generated from cardiovascular magnetic resonance images. The CCPC models were designed by connecting the inferior vena cava and superior vena cava to a shared conduit ascending to the pulmonary arteries, optimized in silico. The 12 total cavopulmonary connection and their corresponding CCPC models underwent in vitro benchtop characterization. Two MCS devices were used, the Impella RP® and the PediPump. RESULTS: MCS successfully and symmetrically reduced the pressure in both vena cavae by >20 mmHg. The devices improved the hepatic flow distribution balance of all CCPC models (Impella RP®P = 0.045, PediPump P = 0.055). CONCLUSIONS: The CCPC Fontan design provides a feasible MCS solution for a failing Fontan by balancing hepatic flow distribution and symmetrically decompressing the central venous pressure. Cardiac index may also improve with MCS. Additional studies are needed to evaluate this concept for managing Fontan failure.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Humanos , Técnica de Fontan/métodos , Veia Cava Superior/cirurgia , Artéria Pulmonar/cirurgia , Veia Cava Inferior/cirurgia , Pulmão/cirurgia , Modelos Cardiovasculares , Hemodinâmica , Cardiopatias Congênitas/cirurgia
10.
Ann Vasc Surg ; 100: 101-109, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38110080

RESUMO

BACKGROUND: Evaluate how specific morphologic aspects of abdominal aortic aneurysms (AAAs), including asymmetries, curvatures, tortuosities, and angulations, among others can influence the intrinsic biomechanical properties of the AAA's wall. This study analyzed the correlation of geometric measurements (1-dimensional, 2-dimensional, and 3-dimensional) of preoperative tomographic images of AAA with uniaxial biomechanical tests of the arterial wall fragments of these AAA obtained in open surgical repair of aneurysms. METHODS: It was a multicenter, experimental, and observational study, and initially 54 individuals were selected who underwent open surgical of AAA, with valid biomechanical tests of the anterior wall of the AAA. Seven individuals were excluded because they had poor preoperative quality computed tomography scans and/or artifacts that impeded image segmentation and extraction of AAA geometric indices. The aortic fragments were subjected to uniaxial biomechanical destructive tests to obtain the following data: maximum load, failure stress, failure tension, failure strain energy, strain, and fragment thickness. In the same patients, preoperative computed tomography scans were performed with the extraction of 26 geometric indices, subdivided into 9 1-dimensional indices, 6 2-dimensional indices, and 11 3-dimensional indices. Data were subjected to statistical analysis using SPSS version 28. RESULTS: Comparing ruptured and unruptured AAA, no statistical difference was observed between the biomechanical and geometric parameters. The fragment thickness of the ruptured AAA was lower than that of the unruptured AAA (P < 0.05). By comparing tomographic geometric indices and biomechanical parameters of the aortic fragments using Pearson's coefficient, positive and linear correlations (P < 0.05) were observed between the geometric variable maximum diameter (Dmax) of the AAA with maximum load (r = 0.408), failure tension (r = 0.372), and failure stress (r = 0.360). Positive and linear correlations were also observed between the variable diameter/height ratio (DHr) and the maximum load (r = 0.360), failure tension (r = 0.354), and failure stress (r = 0.289). The geometric variable DHr was dependent and correlated with Dmax. Simple regression analysis showed that R2 varied between 8.3% and 16.7%, and all models were significant (P < 0.05). CONCLUSIONS: Dmax and DHr were linearly and positively correlated with the resistance parameters (maximum load, failure tension, and failure stress) of the AAA fragments. The DHr variable is dependent and correlated with Dmax. There was no correlation between the other geometric indices and the biomechanical parameters of the AAA wall. The asymmetries did not globally influence the biomechanics of AAA wall; however, they may influence regionally. Larger AAAs were stronger than smaller ones. Therefore, such findings may point toward Dmax is still the main geometric parameter, which influences the anterior wall, and possibly globally in the AAA.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Humanos , Aorta Abdominal/cirurgia , Estresse Mecânico , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia , Resultado do Tratamento , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Fenômenos Biomecânicos , Modelos Cardiovasculares
11.
Braz J Cardiovasc Surg ; 39(1): e20230110, 2023 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-37947184

RESUMO

OBJECTIVE: To define a reference chart comparing pressure drop vs. flow generated by a set of arterial cannulae currently utilized in cardiopulmonary bypass conditions in pediatric surgery. METHODS: Cannulae from two manufacturers were selected considering their design and outer and inner diameters. Cannula performance was evaluated in terms of pressure drop vs. flow during simulated cardiopulmonary bypass conditions. The experimental circuits consisted of a Jostra HL-20 roller pump, a Quadrox-i pediatric oxygenator (Maquet Cardiopulmonary AG, Rastatt, Germany), and a custom pediatric tubing set. The circuit was primed with lactated Ringer's solution only (first condition) and with human packed red blood cells added (second condition) to achieve a hematocrit of 30%. Cannula sizes 8 to 16 Fr were inserted into the cardiopulmonary bypass circuit with a "Y" connector. The flow was adjusted in 100 ml/min increments within typical flow ranges for each cannula. Pre-cannula and post-cannula pressures were measured to calculate the pressure drop. RESULTS: Utilizing a pressure drop limit of 100 mmHg, our results suggest a recommended flow limit of 500, 900, 1400, 2600, and 3100 mL/min for Braile arterial cannulae sizes 8, 10, 12, 14, and 16 Fr, respectively. For Medtronic DLP arterial cannulae sizes 8, 10, 12, 14, and 16 Fr, the recommended flow limit is 600, 1100, 1700, 2700, and 3300 mL/min, respectively. CONCLUSION: This study reinforces discrepancies in pressure drop between cannulae of the same diameter supplied by different manufacturers and the importance of independent translational research to evaluate components' performance.


Assuntos
Cânula , Ponte Cardiopulmonar , Criança , Humanos , Hemodinâmica , Modelos Cardiovasculares , Desenho de Equipamento
12.
Zhonghua Wai Ke Za Zhi ; 61(12): 1114-1118, 2023 Dec 01.
Artigo em Chinês | MEDLINE | ID: mdl-37932148

RESUMO

Aortic dissection is a life-threatening disease with acute onset,rapid progression and high mortality.Hemodynamic factors have important reference value in the development and treatment of aortic dissection.Computational fluid dynamics can intuitively and visually simulate the hemodynamic state of human blood vessels and quantify it numerically.However,computational fluid dynamics without fluid-structure interaction analysis cannot reflect the real situation of the human body.Therefore,the fluid-structure interaction numerical simulation of aortic dissection is worthy of further study to achieve more accurate evaluation of hemodynamic state,postoperative effect and risk prediction.In this paper,the application and research progress of computational fluid dynamics based on fluid-structure interaction technology in aortic dissection are briefly reviewed.


Assuntos
Dissecção Aórtica , Hidrodinâmica , Humanos , Hemodinâmica , Aorta , Simulação por Computador , Modelos Cardiovasculares
13.
Ann Biomed Eng ; 51(12): 2853-2872, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37635154

RESUMO

End-stage Fontan patients with single-ventricle (SV) circulation are often bridged-to-heart transplantation via mechanical circulatory support (MCS). Donor shortage and complexity of the SV physiology demand innovative MCS. In this paper, an out-of-the-box circulation concept, in which the left and right ventricles are switched with each other is introduced as a novel bi-ventricle MCS configuration for the "failing" Fontan patients. In the proposed configuration, the systemic circulation is maintained through a conventional mechanical ventricle assist device (VAD) while the venous circulation is delegated to the native SV. This approach spares the SV and puts it to a new use at the right-side providing the most-needed venous flow pulsatility to the failed Fontan circulation. To analyze its feasibility and performance, eight SV failure modes have been studied via an established multi-compartmental lumped parameter cardiovascular model (LPM). Here the LPM model is experimentally validated against the corresponding pulsatile mock-up flow loop measurements of a representative 15-year-old Fontan patient employing a clinically-approved VAD (Medtronic-HeartWare). The proposed surgical configuration maintained the healthy cardiac index (3-3.5 l/min/m2) and the normal mean systemic arterial pressure levels. For a failed SV with low ejection fraction (EF = 26%), representing a typical systemic Fontan failure, the proposed configuration enabled a ~ 28 mmHg amplitude in the venous/pulmonary waveforms and a 2 mmHg decrease in the central venous pressure (CVP) together with acceptable mean pulmonary artery pressures (17.5 mmHg). The pulmonary vascular resistance (PVR)-SV failure case provided a ~ 5 mmHg drop in the CVP, with venous/pulmonary pulsatility reaching to ~ 22 mmHg. For the high PVR failure case with a healthy SV (EF = 44%) pulmonary hypertension is likely to occur as expected. While this condition is routinely encountered during the heart transplantation and managed through pulmonary vasodilators a need for precise functional assessment of the spared failed-ventricle is recommended if utilized in the PVR failure mode. Comprehensive in vitro and in silico results encourage this novel concept as a low-cost, more physiological alternative to the conventional bi-ventricle MCS pending animal experiments.


Assuntos
Técnica de Fontan , Coração Auxiliar , Animais , Humanos , Adolescente , Ventrículos do Coração , Hemodinâmica/fisiologia , Coração , Resistência Vascular , Modelos Cardiovasculares
14.
Int J Mol Sci ; 24(9)2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37175591

RESUMO

Rheumatoid arthritis (RA) is an autoimmune disease characterised by an attack on healthy cells in the joints. Blood flow and wall shear stress are crucial in angiogenesis, contributing to RA's pathogenesis. Vascular endothelial growth factor (VEGF) regulates angiogenesis, and shear stress is a surrogate for VEGF in this study. Our objective was to determine how shear stress correlates with the location of new blood vessels and RA progression. To this end, two models were developed using computational fluid dynamics (CFD). The first model added new blood vessels based on shear stress thresholds, while the second model examined the entire blood vessel network. All the geometries were based on a micrograph of RA blood vessels. New blood vessel branches formed in low shear regions (0.840-1.260 Pa). This wall-shear-stress overlap region at the junctions was evident in all the models. The results were verified quantitatively and qualitatively. Our findings point to a relationship between the development of new blood vessels in RA, the magnitude of wall shear stress and the expression of VEGF.


Assuntos
Artrite Reumatoide , Fator A de Crescimento do Endotélio Vascular , Humanos , Hidrodinâmica , Hemodinâmica , Estresse Mecânico , Modelos Cardiovasculares
15.
Comput Biol Med ; 158: 106805, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37019010

RESUMO

Cardiovascular diseases are the leading cause of mortality in the world, mainly due to atherosclerosis and its consequences. The article presents the numerical model of the blood flow through artificial aortic valve. The overset mesh approach was applied to simulate the valve leaflets motion and to realize the moving mesh, in the aortic arch and the main branches of cardiovascular system. To capture the cardiac system's response and the effect of vessel compliance on the outlet pressure, the lumped parameter model has been also included within the solution procedure. Three different turbulence modeling approaches were used and compared - the laminar, k-ϵ and k-ω model. The simulation results were also compared with the model excluding the moving valve geometry and the importance of the lumped parameter model for the outlet boundary condition was analyzed. Proposed numerical model and protocol was found as suitable for performing the virtual operations on the real patient vasculature geometry. The time-efficient turbulence model and overall solving procedure allows to support the clinicians in making decisions about the patient treatment and to predict the results of the future surgery.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Hemodinâmica , Resistência Vascular , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo/fisiologia , Simulação por Computador
16.
Biophys J ; 122(8): 1526-1537, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-36932676

RESUMO

The distribution of red blood cells (RBCs) in the microcirculation determines the oxygen delivery and solute transport to tissues. This process relies on the partitioning of RBCs at successive bifurcations throughout the microvascular network, and it has been known since the last century that RBCs partition disproportionately to the fractional blood flow rate, therefore leading to heterogeneity of the hematocrit (i.e., volume fraction of RBCs in blood) in microvessels. Usually, downstream of a microvascular bifurcation, the vessel branch with a higher fraction of blood flow receives an even higher fraction of RBC flux. However, both temporal and time-average deviations from this phase-separation law have been observed in recent studies. Here, we quantify how the microscopic behavior of RBC lingering (i.e., RBCs temporarily residing near the bifurcation apex with diminished velocity) influences their partitioning, through combined in vivo experiments and in silico simulations. We developed an approach to quantify the cell lingering at highly confined capillary-level bifurcations and demonstrate that it correlates with deviations of the phase-separation process from established empirical predictions by Pries et al. Furthermore, we shed light on how the bifurcation geometry and cell membrane rigidity can affect the lingering behavior of RBCs; e.g., rigid cells tend to linger less than softer ones. Taken together, RBC lingering is an important mechanism that should be considered when studying how abnormal RBC rigidity in diseases such as malaria and sickle-cell disease could hinder the microcirculatory blood flow or how the vascular networks are altered under pathological conditions (e.g., thrombosis, tumors, aneurysm).


Assuntos
Eritrócitos , Modelos Cardiovasculares , Hematócrito , Microcirculação/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia
17.
Artif Organs ; 47(5): 828-839, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36310392

RESUMO

BACKGROUND: Pulsatile extracorporeal circulation (ECC) may improve perfusion of critical organs during cardiac surgery. This study analyzed the influence of the components of a minimal invasive ECC (MiECC) on the transfer of pulsatile energy into the pseudo-patient of a mock circulation. METHODS: An aortic model with human-like geometry and compliance was perfused by a diagonal pump. Surplus hemodynamic energy (SHE) was determined from flow and pressure data. Five adult-size oxygenator models and three sizes of cannulas were compared. Pulsatile pump settings were optimized, and parallel dual-pump configurations were evaluated. RESULTS: Oxygenator models showed up to twofold differences in pressure gradients and influenced SHE at flow rates up to 2.0 L min-1 . Adjustments of frequency, systole duration, and rotational speed gain significantly improved SHE compared with empirical settings, with SHE above 21% of mean arterial pressure at flow rates of 1.0 L min-1 to 1.5 L min-1 and SHE above 5% at 3.5 L min-1 . Small diameter cannula (15 Fr) limited SHE compared with larger cannula (21 Fr and 23 Fr). Two diagonal pumps did not provide higher SHE than a single pump, but permitted additional control over pulse pressure and SHE by varying the total fraction of pulsatile flow and the fraction of flow bypassing the oxygenator. CONCLUSIONS: Proper selection of components and optimizations of pump settings significantly improved pulse pressure and SHE of pulsatile MiECC. Surplus hemodynamic energy depended on flow rate with a maximum at 1.0 L min-1 -1.5 L min-1 . Pulsatile MiECC may specifically assist organ perfusion during phases of low flow.


Assuntos
Oxigenação por Membrana Extracorpórea , Adulto , Humanos , Modelos Cardiovasculares , Circulação Extracorpórea , Hemodinâmica , Perfusão , Fluxo Pulsátil
18.
Ann Biomed Eng ; 51(1): 270-289, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36326994

RESUMO

Recently a lumped-parameter model of the cardiovascular system was proposed to simulate the hemodynamics response to partial hepatectomy and evaluate the risk of portal hypertension (PHT) due to this surgery. Model parameters are tuned based on each patient data. This work focuses on a global sensitivity analysis (SA) study of such model to better understand the main drivers of the clinical outputs of interest. The analysis suggests which parameters should be considered patient-specific and which can be assumed constant without losing in accuracy in the predictions. While performing the SA, model outputs need to be constrained to physiological ranges. An innovative approach exploits the features of the polynomial chaos expansion method to reduce the overall computational cost. The computed results give new insights on how to improve the calibration of some model parameters. Moreover the final parameter distributions enable the creation of a virtual population available for future works. Although this work is focused on partial hepatectomy, the pipeline can be applied to other cardiovascular hemodynamics models to gain insights for patient-specific parameterization and to define a physiologically relevant virtual population.


Assuntos
Hepatectomia , Modelos Cardiovasculares , Humanos , Hemodinâmica , Algoritmos
19.
Comput Methods Biomech Biomed Engin ; 26(2): 209-221, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35414317

RESUMO

The accuracy of the Newtonian model used in retrograde visceral revascularization (RVR) of hybrid surgery for thoracoabdominal aortic aneurysm (TAAA) hemodynamic simulation remains unclear. Noting that an appropriate blood viscosity model is a significant factor to capture hemodynamic changes in numerical studies. Therefore, both Newtonian and non-Newtonian blood viscosity models were adopted in this study to investigate the importance of hemodynamics when non-Newtonian blood property was accounted for in a patient-specific RVR simulation. The results revealed that disturbed flow and unfavorable WSS distribution can be observed in the anastomosis region under both blood viscosity models due to the retrograde flow pattern in the RVR model. However, although the non-Newtonian blood model has negligible effect on flow pattern and pressure drop, there were of significance quantitative and qualitative difference of local normalized helicity and wall shear stress distribution under pulsatile flow condition. In particular, the unfavorable WSS indicators distribution was better matched with a patient-specific follow-up report when non-Newtonian blood viscosity was accounted for. To conclude, the use of a Newtonian blood model is a reasonable approximation to obtain the general features of the flow field under steady flow condition. However, to study the hemodynamic parameters within retrograde flow under pulsatile flow condition, a non-Newtonian model may be more appropriate.


Assuntos
Aneurisma da Aorta Toracoabdominal , Humanos , Modelos Cardiovasculares , Hemodinâmica , Fluxo Pulsátil , Simulação por Computador , Estresse Mecânico , Velocidade do Fluxo Sanguíneo
20.
Vasc Endovascular Surg ; 57(1): 26-34, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36083843

RESUMO

Background and aims: This study describes and demonstrates the applicability of a novel in silico method for modeling progressive carotid artery stenosis using the oscillatory shear index (OSI) as the basis of stenosis. Methods: Three-dimensional reconstructions of 11 carotid arteries were generated using patient-derived magnetic resonance angiography and duplex ultrasound data. Computational fluid dynamic simulations were sequentially generated following computational stenosis assessment, and corresponding changes in OSI were observed and used as measure of morphological stabilization. Results: 6 carotid models showed progressive stenosis with statistically significant increases in regions of high OSI (OSI >.2, P < .05) with eventual carotid occlusion in 1 of the cases. Three models remained free or nearly free of increased OSI, whereas 1 model showed an overall decrease in high OSI regions (P < .05) and another trended in that direction but did not achieve statistical significance (P = .145). Conclusions: To our knowledge, this is the first computational model describing progressive stenosis in any peripheral artery including the carotid. Taken together, this study provides a novel framework for computational hemodynamic investigations on progressive atherosclerosis in the carotid artery.


Assuntos
Estenose das Carótidas , Humanos , Estenose das Carótidas/diagnóstico por imagem , Constrição Patológica , Modelos Cardiovasculares , Fluxo Sanguíneo Regional , Resultado do Tratamento , Artérias Carótidas , Hemodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA